• DocumentCode
    840759
  • Title

    Analysis of Reset Discharge Characteristics in AC-Plasma Display Panel With Various Sustain Gaps Using V_{t} Close-Curve

  • Author

    Park, Ki-Hyung ; Tae, Heung-Sik ; Seo, Jeong Hyun

  • Author_Institution
    Sch. of Electr. Eng. & Comput. Sci., Kyungpook Nat. Univ., Daegu
  • Volume
    55
  • Issue
    9
  • fYear
    2008
  • Firstpage
    2329
  • Lastpage
    2337
  • Abstract
    The effects of various sustain gaps on the reset discharge characteristics, particularly the discharge stability, are examined based on a Vt close-curve analysis. The Vt close-curve analysis shows that the reset discharge region producing a stable discharge under an MgO cathode condition is reduced in proportion to the increase in the sustain gap, resulting in discharge instability when a conventional reset waveform is applied with a wide-sustain-gap (over 200 mum) structure. Based on the Vt close-curve analysis, a modified reset waveform suitable for a wide-sustain-gap (= 200 mum) structure is proposed to prevent an unstable discharge. The effects of two parameters Vadd-bias and Vcom-bias in the modified reset waveform on the reset discharge as well as the address and first sustain discharges, are examined in detail.
  • Keywords
    discharges (electric); magnesium compounds; plasma displays; AC-plasma display panel; MgO; close-curve analysis; discharge instability; discharge stability; reset discharge region; wide-sustain-gap structure; Cathodes; Character generation; Displays; Electrodes; Engines; Image analysis; Phosphors; Pulse generation; Stability analysis; Surface discharges; $V_{t}$ close-curve analysis; Discharge stability; modified reset waveform; various sustain gaps; wide-sustain-gap of 200 $muhbox{m}$;
  • fLanguage
    English
  • Journal_Title
    Electron Devices, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9383
  • Type

    jour

  • DOI
    10.1109/TED.2008.927947
  • Filename
    4603180