Abstract :
Tricresyl phosphate (TCP), a phosphate ester with fire-resistant and insulating properties, is proposed as a cable cooling medium. A field test was performed with a 275 kV internally-oil-cooled, oil-filled (OF) power cable system using TCP, and it was ascertained that the cable system meets requirements for ease of installation, cooling characteristics, and long-term stability of the cable and the long-term stability of the cable and the TCP. The series of tests has demonstrated the practicality of the cable system.<>
Keywords :
cable insulation; cable testing; insulating oils; power cables; 275 kV; cable cooling; cable testing; installation; insulating oils; stability; tricresyl phosphate; Conductors; Coolants; Cooling; Fires; Oil filled cables; Oil insulation; Petroleum; Power cable insulation; Power cables; System testing;