DocumentCode :
845400
Title :
Quasi-optical measurement of carcinotron phase noise at 350 GHz
Author :
van Ardenne, A.
Author_Institution :
Netherlands Found. for Radio Astron., Dwingeloo
Volume :
24
Issue :
23
fYear :
1988
fDate :
11/10/1988 12:00:00 AM
Firstpage :
1411
Lastpage :
1413
Abstract :
Phase noise of a single carcinotron operating at 350 GHz, at offset frequencies in the range 105-107 Hz, from the carrier has been measured. A quasi-optical analogue of the delay line frequency discriminator method was used, demonstrating a simple method capable of measuring phase noise in the (sub)mm region. The results obtained are of practical use in the design of phase locked systems, in the wavelength region used
Keywords :
calibration; carcinotrons; electron device noise; electron tube testing; microwave measurement; submillimetre wave devices; 350 GHz; EHF; MM-wave operation; PLL design; backward wave oscillator; calibration; carcinotron; delay line frequency discriminator method; microwave tubes; phase locked systems; phase noise; quasioptical measurement; submillimetre wave type;
fLanguage :
English
Journal_Title :
Electronics Letters