• DocumentCode
    845400
  • Title

    Quasi-optical measurement of carcinotron phase noise at 350 GHz

  • Author

    van Ardenne, A.

  • Author_Institution
    Netherlands Found. for Radio Astron., Dwingeloo
  • Volume
    24
  • Issue
    23
  • fYear
    1988
  • fDate
    11/10/1988 12:00:00 AM
  • Firstpage
    1411
  • Lastpage
    1413
  • Abstract
    Phase noise of a single carcinotron operating at 350 GHz, at offset frequencies in the range 105-107 Hz, from the carrier has been measured. A quasi-optical analogue of the delay line frequency discriminator method was used, demonstrating a simple method capable of measuring phase noise in the (sub)mm region. The results obtained are of practical use in the design of phase locked systems, in the wavelength region used
  • Keywords
    calibration; carcinotrons; electron device noise; electron tube testing; microwave measurement; submillimetre wave devices; 350 GHz; EHF; MM-wave operation; PLL design; backward wave oscillator; calibration; carcinotron; delay line frequency discriminator method; microwave tubes; phase locked systems; phase noise; quasioptical measurement; submillimetre wave type;