Title :
Evaluation and utilization of the Josephson array
Author :
Wood, Barry ; Inglis, A.D. ; Dunn, A.F.
Author_Institution :
Nat. Res. Council of Canada, Ottawa, Ont., Canada
fDate :
4/1/1989 12:00:00 AM
Abstract :
A system using a Josephson series array capable of developing voltages of up to 1.3 V is described. The array system has been compared to the volt of the NRC (National Research Council of Canada), or VNRC with good agreement. At 1.018 V, the difference between the array system and VNRC, which is referenced to an existing single junction system, is 0.008±0.035 μV
Keywords :
Josephson effect; measurement standards; voltage measurement; 1.018 V; 1.3 V; Josephson array; voltage measurement standard; Counting circuits; Frequency; Helium; Josephson effect; Microwave antenna arrays; Monitoring; Probes; Superconducting microwave devices; Voltage; Water storage;
Journal_Title :
Instrumentation and Measurement, IEEE Transactions on