DocumentCode :
845494
Title :
A 10-V Josephson voltage standard
Author :
Hamilton, Clark A. ; Lloyd, Frances L. ; Chieh, Kao ; Goeke, Wayne C.
Author_Institution :
NBS, Boulder, CO, USA
Volume :
38
Issue :
2
fYear :
1989
fDate :
4/1/1989 12:00:00 AM
Firstpage :
314
Lastpage :
316
Abstract :
The design and operation of an 18992-Josephson-junction array, which can generate reference voltages up to 12 V, is described. This device has applications for the direct calibration of Zener reference standards, calibrators, and digital voltmeters at the 10-V level, and for very accurate linearity and ratio measurements. The modified design of the array resolves the problems of stability and power requirement
Keywords :
Josephson effect; measurement standards; superconducting junction devices; voltage measurement; 10 V; Josephson voltage standard; Zener reference standards; calibration; digital voltmeters; linearity; measurement standard; power; ratio measurements; stability; Calibration; Critical current; Fabrication; Josephson junctions; Linearity; Measurement standards; Microstrip; Stability; Voltage; Voltmeters;
fLanguage :
English
Journal_Title :
Instrumentation and Measurement, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9456
Type :
jour
DOI :
10.1109/19.192296
Filename :
192296
Link To Document :