• DocumentCode
    845635
  • Title

    Determination of AC-DC difference in the 0.1-100 MHz frequency range

  • Author

    Kinard, Joseph R. ; Cai, Ti-Xiong

  • Author_Institution
    NBS, Gaithersburg, MD, USA
  • Volume
    38
  • Issue
    2
  • fYear
    1989
  • fDate
    4/1/1989 12:00:00 AM
  • Firstpage
    360
  • Lastpage
    367
  • Abstract
    Thermal voltage converter structures have been modeled theoretically and studied experimentally to determine their AC-DC differences in the 0.1-100-MHz frequency range. Estimated uncertainties, corresponding to the one standard deviation confidence level, for these AC-DC differences vary from 20 p.p.m. at 1 MHz to 2000 p.p.m. at 100 MHz
  • Keywords
    convertors; electric current measurement; measurement standards; voltage measurement; 0.1 to 100 MHz; AC-DC difference; thermal voltage convertor; Analog-digital conversion; Connectors; Frequency conversion; NIST; Region 1; Region 2; Resistors; Skin effect; Thermal resistance; Voltage;
  • fLanguage
    English
  • Journal_Title
    Instrumentation and Measurement, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9456
  • Type

    jour

  • DOI
    10.1109/19.192307
  • Filename
    192307