Abstract
In the Fermilab Main Ring power supply system, we have added ZNR type (zinc oxide nonlinear resistor) suppressors to each power supply terminal to limit the magnet voltage-to-ground to 2.1 kV. The ZNR´s conduct 50 A at the 2.1 kV clipping voltage, and leak less than 1 mA at the 1.5 kV maximum operating voltage. Their repetitive surge rating is 1.4 kJ. Their main advantage, in comparison to spark gaps, is that the ZNR´s do not break down and cause transients and high voltages at neighboring points on the magnet bus.