• DocumentCode
    847908
  • Title

    Objective analysis of ultrasound images by use of a computational observer

  • Author

    LOPEZ, HECTOR ; Loew, Murray H. ; Goodenough, David J.

  • Author_Institution
    Center for Devices & Radiol. Health, Food & Drug Adm., Rockville, MD, USA
  • Volume
    11
  • Issue
    4
  • fYear
    1992
  • fDate
    12/1/1992 12:00:00 AM
  • Firstpage
    496
  • Lastpage
    506
  • Abstract
    The design, implementation, and testing of a computational observer method for objective evaluation of ultrasound images are presented. The method uses digitized ultrasound B-scan images of a test phantom (the contrast-detail phantom), and is able to calculate the detectability of a target (signal) from its background (background noise). A quantitative detectability index, based on the measured signal-to-noise ratio of the image data, that is measured for both the human and the computational observer on the same scale is generated. It is shown that the computational observer (CO) method may be a more useful, objective way of evaluating ulrasound images and imaging systems than methods that rely solely on human observers. It may also be applicable to other types (i.e. other than ultrasound) of imaging systems which produce noisy images. The relevance of the CO method when compared to human observer two-alternative-forced-choice (2AFC) readings of the same data by showing a high correlation between the CO detectability results and those of human observers for the same set of images. The method is (1) quantitative, (2) reproducible, (3) absolute, (4) takes into account, and can calculate the value of TPF and FPF for each target, for the given system, and (5) speeds up the evaluation of an image or imaging system (compared to using human observers), given the right conditions and equipment
  • Keywords
    acoustic imaging; biomedical ultrasonics; medical diagnostic computing; medical image processing; 2-alternative-forced-choice readings; background noise; computational observer method; contrast-detail phantom; digitized ultrasound B-scan images; human observer; medical diagnostic imaging; noisy images; objective image evaluation; quantitative detectability index; signal-to-noise ratio; target detectability; test phantom; Background noise; Gas detectors; Humans; Image analysis; Imaging phantoms; Signal generators; Signal to noise ratio; Testing; Ultrasonic imaging; Ultrasonic variables measurement;
  • fLanguage
    English
  • Journal_Title
    Medical Imaging, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0278-0062
  • Type

    jour

  • DOI
    10.1109/42.192685
  • Filename
    192685