DocumentCode :
847978
Title :
Development of Silica Aerogel Cerenkov Detectors
Author :
Carlson, P.J. ; Johansson, K.E. ; Norrby, J.
Author_Institution :
University of Stockholm, Institute of Physics Vanadisvÿgen 9, S-113 46 Stockholm, Sweden
Volume :
27
Issue :
1
fYear :
1980
Firstpage :
96
Lastpage :
100
Abstract :
Recently silica aerogel has been employed as a Cerenkov radiator. This solid material can be produced with a refractive index of 1.01-1.10, thus complementing the refractive indices easily obtained with gases and liquids. It is very well suited for identification of particles having momenta of about one or a few GeV/c. Examples of efficient detectors with active surfaces of about 0.1 m2 using light collection system constructed from mirrors and diffusing walls are given. With a refractive index of 1.03 and an aerogel thickness of 9 cm, signals of about 6 photoelectrons have been obtained for ß = 1 particles.
Keywords :
Absorption; Counting circuits; Detectors; Gases; Liquids; Optical refraction; Refractive index; Silicon compounds; Solids; Wavelength measurement;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/TNS.1980.4330810
Filename :
4330810
Link To Document :
بازگشت