Title :
Breakdown phenomena of long gaps under switching impulse conditions time to breakdown distribution and breakdown probability: Statistical approach
Author :
Hutzler, B. ; Hutzler, D.
Author_Institution :
Electricite de France, Paris
Volume :
94
Issue :
3
fYear :
1975
fDate :
5/1/1975 12:00:00 AM
Firstpage :
894
Lastpage :
898
Abstract :
Starting from experimental results on final jump and using physical interpretations of first corona and leader process, a computer aided method is proposed to determine a "limit-volt-time" curve. Furthermore, it is shown that the time to breakdown, U50and σU50can be deduced once the impulse shape applied to a given gap is known provided that one utilizes the "intrinsic probability density" concept.
Keywords :
Corona; Electric breakdown; Electrodes; Electrons; Printing; Probability; Shape; Societies; Testing; Voltage;
fLanguage :
English
Journal_Title :
Power Apparatus and Systems, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9510
Type :
jour
DOI :
10.1109/T-PAS.1975.31920