Title :
Design of an Isotopic CT Scanner for Two Phase Flow Measurements
Author :
De Vuono, A.C. ; Schlosser, P.A. ; Kulacki, F.A. ; Munshi, P.
Author_Institution :
Nuclear Engineering the Ohio State University Columbus, Ohio 43210
Abstract :
A feasibility study including parametric analysis, bubbly flow experimentation and preliminary hardware design has been completed for an isotopic CT scanner to interrogate two phase flows. The study results indicate a high speed fan beam scanner is feasible for measuring two phase flows under transient conditions by performing sequential scans. The major tradeoffs of this device compared to medical scanners are spatial resolution (1.15 cm), density resolution (3%), and source type (Cesium-137).
Keywords :
Aluminum; Collimators; Computed tomography; Current measurement; Engine cylinders; Fluid flow measurement; Phase measurement; Reactor instrumentation; Spatial resolution; Velocity measurement;
Journal_Title :
Nuclear Science, IEEE Transactions on
DOI :
10.1109/TNS.1980.4330933