DocumentCode
84999
Title
New Testing Methodology of an Analog to Digital Converter for the LHC Mixed Radiation Field
Author
Danzeca, S. ; Dusseau, L. ; Peronnard, P. ; Spiezia, G.
Author_Institution
Eur. Organ. for Nucl. Res. (CERN), Genève, Switzerland
Volume
60
Issue
4
fYear
2013
fDate
Aug. 2013
Firstpage
2598
Lastpage
2604
Abstract
In this work a commercial off the shelf Analog to Digital Converter (ADC), based on a Successive Approximation Register (SAR) structure, has been tested to verify Total Ionizing Dose (TID) effects and evaluate Single Event Upset (SEU) and Single Event Latch-up (SEL) cross sections. A well-known test is used to verify the SEU cross section with a constant input voltage; a new test method is proposed to measure the dynamic ADC performance, such as the Effective Number Of Bit (ENOB), continuously during the irradiation. The tests have been carried out at the Paul Scherrer Institute (PSI) beam facility at 230 MeV, at CERN in a dedicated experimental area that recreates the same radiation environment of the Large Hadron Collider (LHC) tunnel, and at a heavy ion facility, especially for defining the SEL risk.
Keywords
analogue-digital conversion; dosimetry; radiation effects; ADC; CERN; ENOB; LHC mixed radiation field; LHC tunnel; Large Hadron Collider; Paul Scherrer Institute beam facility; SEL risk; SEU cross section; analog-to-digital converter; effective number-of-bit; electron volt energy 230 MeV; heavy ion facility; radiation environment; single event latch-up cross sections; single event upset cross sections; successive approximation register structure; total ionizing dose effect; Calibration; Large Hadron Collider; Monitoring; Particle beams; Radiation effects; Single event upsets; A/D; COTS; TID; analog to digital converter; analog-digital integrated circuits; mixed-radiation field; single event upset;
fLanguage
English
Journal_Title
Nuclear Science, IEEE Transactions on
Publisher
ieee
ISSN
0018-9499
Type
jour
DOI
10.1109/TNS.2013.2261825
Filename
6522548
Link To Document