DocumentCode :
850601
Title :
A Laboratory Experimental Technique for Determining Satellite Cable Response to SGEMP
Author :
Chadsey, W.L. ; Tigner, J.E. ; Miller, R.I. ; Smith, P.
Author_Institution :
Technological Systems Group Science Applications, Inc. 8330 Old Courthouse Road, Suite 510 Vienna, Virginia 22180
Volume :
27
Issue :
6
fYear :
1980
Firstpage :
1547
Lastpage :
1551
Abstract :
An experimental technique has been developed which uses a continuous, low-level, X-ray source to determine the direct drive SGEMP response of satellite cables. Preliminary experimental results are presented for three types of cables. The direct drive responses obtained in the continuous X-ray experiments are compared with responses obtained in flash X-ray and underground test experiments.
Keywords :
Cable shielding; Communication cables; Drives; Laboratories; Power cables; Predictive models; Pulse generation; Satellites; Testing; Uncertainty;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/TNS.1980.4331067
Filename :
4331067
Link To Document :