DocumentCode
851583
Title
A 16-channel analog integrated circuit for PMT pulse processing
Author
Gallin-Martel, L. ; Pouxe, J. ; Rossetto, O. ; Yamouni, M.
Author_Institution
Inst. des Sci. Nucl., Grenoble, France
Volume
49
Issue
4
fYear
2002
fDate
8/1/2002 12:00:00 AM
Firstpage
1798
Lastpage
1801
Abstract
In this paper, we present an integrated circuit designed for photomultiplier tube (PMT) pulse processing. This circuit was developed for the RICH detector of the AMS experiment. It integrates 16 identical channels and has to deal with space environment constraints (low power consumption, radiation hardness). It processes the 16 analog signals coming from anodes of a multianode PMT and the signal coming from a dynode. It integrates a control logic for the multiplexing of the output data. A test mode can be activated for the calibration of each channel. An offset cancellation system has been designed for the dynode channel. This offset cancellation is important in order to avoid thermal drifts and offset spreads.
Keywords
CMOS analogue integrated circuits; Cherenkov counters; nuclear electronics; photomultipliers; 16-channel analog integrated circuit; AMS experiment; RICH detector; dynode channel; offset cancellation system; offset spreads; photomultiplier tubes pulse processing; power consumption; radiation hardness; space environment constraints; thermal drifts; Analog integrated circuits; Anodes; Calibration; Detectors; Energy consumption; Logic; Photomultipliers; Pulse circuits; Signal processing; Testing;
fLanguage
English
Journal_Title
Nuclear Science, IEEE Transactions on
Publisher
ieee
ISSN
0018-9499
Type
jour
DOI
10.1109/TNS.2002.801533
Filename
1043511
Link To Document