DocumentCode :
851641
Title :
Digital pulse-shape algorithms for scintillation-based neutron detectors
Author :
Jastaniah, S.D. ; Sellin, P.J.
Author_Institution :
Dept. of Phys., Surrey Univ., Guildford, UK
Volume :
49
Issue :
4
fYear :
2002
fDate :
8/1/2002 12:00:00 AM
Firstpage :
1824
Lastpage :
1828
Abstract :
We discuss the application of digital pulse shape algorithms to n/γ pulse shape discrimination (PSD) in boron-10 enriched liquid scintillator, where the use of digital techniques has potential applications for neutron monitors. High-speed flash analog-to-digital converters have opened up new possibilities for scintillator detector systems based upon digital event-by-event data acquisition. Using an 8-bit 1-GS/s waveform digitizer, we sampled the scintillation detector signals with nanosecond time resolution to extract event parameters such as pulse height and rise time. Hence, we have studied the variations in pulse shape and rise times for gamma rays and neutrons and the quality of separation of these events. Even using a simple 10-90% rise-time algorithm, we observe good gamma/neutron separation. We present the PSD figure-of-merit obtained using this digital technique.
Keywords :
gamma-ray detection; neutron detection; pulse shaping; solid scintillation detectors; 10B; B; BC523A; digital pulse shape algorithms; figure-of-merit; flash ADC; gamma/neutron separation; neutron gamma pulse shape discrimination; pulse height; rise time; scintillation neutron detectors; waveform digitizer; Analog-digital conversion; Data acquisition; Data mining; Neutrons; Pulse shaping methods; Scintillation counters; Shape; Signal detection; Signal resolution; Solid scintillation detectors;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/TNS.2002.801674
Filename :
1043522
Link To Document :