DocumentCode :
851977
Title :
Criteria for determining performance in service of crosslinked polyethylene insulated power cables
Author :
Bahder, G. ; Eager, G.S. ; Silver, D.A. ; Lukac, R.G.
Author_Institution :
General Cable Corporation Union, New Jersey
Volume :
95
Issue :
5
fYear :
1976
Firstpage :
1552
Lastpage :
1566
Abstract :
This paper presents results of a study on the mechanism of failure of crosslinked polyethylene (XLP) power cable. The n factor which establishes a basis for prediction of voltage stress-time characteristics is determined. The influence of the environment and normal operating conditions on voltage-time characteristics of XLP is presented. Recommendations are offered for an effective factory testing program for XLP insulated power cable.
Keywords :
Cable insulation; Cable shielding; Dielectric breakdown; Dielectrics and electrical insulation; Plastic insulation; Polyethylene; Power cable insulation; Power cables; Stress; Voltage;
fLanguage :
English
Journal_Title :
Power Apparatus and Systems, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9510
Type :
jour
DOI :
10.1109/T-PAS.1976.32254
Filename :
1601856
Link To Document :
بازگشت