Title :
A Gas Ionization Sampling Electromagnetic Shower Detector
Author :
Atac, M. ; Hanssen, D. ; Jensen, H. ; Tollestrup, A. ; Urish, J. ; Kennett, R.G. ; Walker, R. ; Nodulman, L.
Author_Institution :
Fermi National Accelerator Laboratory, Batavia, IL 60510
Abstract :
The results of the tests of a prototype ionization sampling calorimeter are presented. Using proportional chmbers interleaved with lead and sampling every 0.68 radiation length, we found an energy resolution of 24%/¿E. Measurements of position resolution, lateral shower developent, and hadron rejection are discussed.
Keywords :
Circuits; Foot; Gain measurement; Hydrogen; Ionization; Magnetic analysis; Monitoring; Pulse amplifiers; Sampling methods; Wires;
Journal_Title :
Nuclear Science, IEEE Transactions on
DOI :
10.1109/TNS.1981.4331227