DocumentCode
852653
Title
An Operational Model for Microchannel Plate Devices
Author
Eberhardt, E.H.
Author_Institution
ITT/Electro-Optical Products Division Tube and Sensor Laboratories 3700 E. Pontiac Street Fort Wayne, Indiana 46803
Volume
28
Issue
1
fYear
1981
Firstpage
712
Lastpage
717
Abstract
The behavior of optical detectors using microchannel plates (MCPs) as electron multipliers is described in terms of the physical parameters of the MCP (channel resistance, channel capacitance, channel wall secondary emission ratio, etc.). Three operating modes are included: (1) DC operation at low light levels, (2) pulse detection operation at high peak currents, and (3) single electron counting with cascaded V-plate and Z-plate MCPs.
Keywords
Electron emission; Electron multipliers; Electron tubes; Electrooptic devices; Gain measurement; Image intensifiers; Microchannel; Predictive models; Pulse amplifiers; Voltage;
fLanguage
English
Journal_Title
Nuclear Science, IEEE Transactions on
Publisher
ieee
ISSN
0018-9499
Type
jour
DOI
10.1109/TNS.1981.4331267
Filename
4331267
Link To Document