Title :
A Microcomputer-Based Equipment Control and Data Acquisition System for Fission-Reactor Reactivity-Worth Measurements
Author :
McDowell, William P. ; Bucher, R.G.
Author_Institution :
Electronics Division Argonne National Laboratory Argonne, Illinois, U.S.A.
Abstract :
Material reactivity-worth measurements are one of the major classes of experiments conducted on the Zero Power research reactors (ZPR) at Argonne National Laboratory. These measurements require the monitoring of the position of a servo control element as a sample material is positioned at various locations in a critical reactor configuration. In order to guarantee operational reliability and increase experimental flexibility for these measurements, the obsolete hardware-based control unit has been replaced with a microcomputer based equipment control and data acquisition system. This system is based on an S-100 bus, dual floppy disk computer with custom built cards to interface with the experimental system. To measure reactivity worths, the system accurately positions samples in the reactor core and acquires data on the position of the servo control element. The data are then analyzed to determine statistical adequacy. The paper covers both the hardware and software aspects of the design.
Keywords :
Conducting materials; Control systems; Data acquisition; Inductors; Laboratories; Monitoring; Position measurement; Power measurement; Power system reliability; Servosystems;
Journal_Title :
Nuclear Science, IEEE Transactions on
DOI :
10.1109/TNS.1981.4331276