DocumentCode
854246
Title
New modified polyethylene paper proposed for UHV cable insulation
Author
Iwata, Z. ; Shii, H. ; Kinoshita, M. ; Hirukawa, H. ; Kawai, E.
Author_Institution
The Furukawa Electric Co., Ltd., Yokohama, Japan
Volume
96
Issue
5
fYear
1977
Firstpage
1573
Lastpage
1582
Abstract
Polyethylene is the most popular and excellent material for electrical insulation. But on account of its poor resistance to oil, polyethylene is considered not suitable for the insulation of oil filled cable. We succeeded in developing a new modified polyethylene paper (FHCP), which has an extremely improved compatibility with oil, while retaining its excellent properties. This new paper will have the electrical and mechanical properties required for UHV cable insulation.
Keywords
Cable insulation; Dielectric breakdown; Dielectric losses; Dielectrics and electrical insulation; Electric resistance; Oil filled cables; Petroleum; Plastic insulation; Polyethylene; Propagation losses;