• DocumentCode
    854796
  • Title

    Radiation Safety at a Neutron Generator

  • Author

    Rank, Edward X.

  • Author_Institution
    Naval Research Laboratory, Washington, D. C. 20375
  • Volume
    28
  • Issue
    2
  • fYear
    1981
  • fDate
    4/1/1981 12:00:00 AM
  • Firstpage
    1603
  • Lastpage
    1605
  • Abstract
    From our experience with the radiation safety problems created at NRL by accelerator neutrons, we have drawn certain general conclusions. The first is that neutron dosimetry is not a stra ightforward process. In general given "the state of the art" the neutron dose is not easily determined and any neutron measurement should be treated with a great deal of skepticism. At NRL we take a very conservative approach to neutron doses, usually requiring that neutron dose rates be a factor of five below allowable limits. The activation problem at a neutron-producing accelerator is also significant. In order to keep personnel doses as low as possible it is necessary to maintain strict control over target materials and entry into a target area. Finally the design of shielding at a neutron facility must be given careful consideration by as many people as can be assembled who are familiar with the strange quirrks of scattering neutrons.
  • Keywords
    Calibration; Cyclotrons; Dosimetry; Instruments; Laboratories; Linear particle accelerator; Neutrons; Personnel; Q factor; Radiation safety;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.1981.4331477
  • Filename
    4331477