DocumentCode :
856283
Title :
High-performance 3D median filter architecture for medical image despeckling
Author :
Jiang, M. ; Crookes, D.
Author_Institution :
Sch. of Electron., Queen´´s Univ. Belfast
Volume :
42
Issue :
24
fYear :
2006
Firstpage :
1379
Lastpage :
1380
Abstract :
A high-sample rate 3D median filtering processor architecture is proposed, based on a novel 3D median filtering algorithm, that can reduce the computing complexity in comparison with the traditional bubble sorting algorithm. A 3times3times3 filter processor is implemented in VHDL, and the simulation verifies that the processor can process a 128times128times96 MRI image in 0.03 seconds while running at 50 MHz
Keywords :
biomedical MRI; hardware description languages; image denoising; median filters; medical image processing; 0.03 s; 3D median filter; 50 MHz; VHDL; computing complexity; filter processor; medical image despeckling;
fLanguage :
English
Journal_Title :
Electronics Letters
Publisher :
iet
ISSN :
0013-5194
Type :
jour
DOI :
10.1049/el:20062357
Filename :
4027902
Link To Document :
بازگشت