Abstract
A 16-plane multiwire proportional chamber is used to accurately measure intensity profiles of heavy ion beams at the Bevalac. An imaging capability has now been developed for the system, allowing for reconstruction of 3-dimensional representation of radiological objects using heavy ion beams.