• DocumentCode
    85738
  • Title

    A Source-Current-Detected Shunt Active Power Filter Control Scheme Based on Vector Resonant Controller

  • Author

    Hao Yi ; Fang Zhuo ; Yanjun Zhang ; Yu Li ; Wenda Zhan ; Wenjie Chen ; Jinjun Liu

  • Author_Institution
    Dept. of Ind. Autom., Xi´an Jiaotong Univ., Xi´an, China
  • Volume
    50
  • Issue
    3
  • fYear
    2014
  • fDate
    May-June 2014
  • Firstpage
    1953
  • Lastpage
    1965
  • Abstract
    A shunt active power filter (APF) with current detection at the source side is considered as a closed-loop system from the view of the whole power distribution system, which is expected with better harmonics filtering performance compared with the one with load current detection. The conventional source current detection control scheme can be mainly grouped into two types: 1) current-source-based (CS) scheme and 2) power-balance-based (PB) scheme. As introduced in this paper, the CS scheme has good dc-voltage regulation, but it bears inevitable conflict between filtering performance and system stability, whereas the PB scheme has excellent stable filtering performance, but it bears great influence on the dc voltage in the transient state. In this paper, a novel source current detection control scheme is proposed, which reserves the advantages of conventional schemes and, meanwhile, avoids their limitations. The proposed scheme employs a vector resonant controller, with which the shunt APF performs as an equivalent multiband rejection filter that series between nonlinear loads and the grid source, blocking selected harmonics components from the load side flowing into the source side. The proposed scheme is simple in structure, is needless of a harmonics extraction algorithm, and shows good stable and transient performance. Finally, the conclusions obtained in this paper are validated through experiments on the laboratory prototype.
  • Keywords
    closed loop systems; distribution networks; power harmonic filters; power system transients; closed-loop system; current-source-based scheme; dc voltage; dc-voltage regulation; equivalent multiband rejection filter; grid source; harmonics components; harmonics extraction algorithm; harmonics filtering performance; load current detection; load side; nonlinear loads; power-balance-based scheme; shunt APF performs; source current detection control scheme; source side; source-current-detected shunt active power filter control scheme; system stability; transient performance; transient state; vector resonant controller; whole power distribution system; Bandwidth; Harmonic analysis; Inductors; Resonant frequency; Shunts (electrical); Tracking loops; Closed-loop system; closed-loop system; resonant controller; shunt active power filter; shunt active power filter (APF); source current detection;
  • fLanguage
    English
  • Journal_Title
    Industry Applications, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0093-9994
  • Type

    jour

  • DOI
    10.1109/TIA.2013.2289956
  • Filename
    6657786