DocumentCode :
858451
Title :
Fast Large-Tip-Angle Multidimensional and Parallel RF Pulse Design in MRI
Author :
Grissom, William A. ; Xu, Dan ; Kerr, Adam B. ; Fessler, Jeffrey A. ; Noll, Douglas C.
Author_Institution :
Inf. Syst. & Radiol. Sci. Labs., Stanford Univ., Stanford, CA, USA
Volume :
28
Issue :
10
fYear :
2009
Firstpage :
1548
Lastpage :
1559
Abstract :
Large-tip-angle multidimensional radio-frequency (RF) pulse design is a difficult problem, due to the nonlinear response of magnetization to applied RF at large tip-angles. In parallel excitation, multidimensional RF pulse design is further complicated by the possibility for transmit field patterns to change between subjects, requiring pulses to be designed rapidly while a subject lies in the scanner. To accelerate pulse design, we introduce a fast version of the optimal control method for large-tip-angle parallel excitation. The new method is based on a novel approach to analytically linearizing the Bloch equation about a large-tip-angle RF pulse, which results in an approximate linear model for the perturbations created by adding a small-tip-angle pulse to a large-tip-angle pulse. The linear model can be evaluated rapidly using nonuniform fast Fourier transforms, and we apply it iteratively to produce a sequence of pulse updates that improve excitation accuracy. We achieve drastic reductions in design time and memory requirements compared to conventional optimal control, while producing pulses of similar accuracy. The new method can also compensate for nonidealities such as main field inhomogeneties.
Keywords :
biomedical MRI; perturbation theory; Bloch equation; MRI; large-tip-angle radio-frequency pulse design; magnetization nonlinear response; multidimensional radio-frequency pulse design; nonuniform fast Fourier transform; parallel RF pulse design; perturbations; Algorithm design and analysis; Equations; Fast Fourier transforms; Information systems; Linear approximation; Magnetic resonance imaging; Multidimensional systems; Nonuniform electric fields; Optimal control; Radio frequency; Large-tip-angle RF pulse design; RF pulse design; magnetic resonance imaging (MRI); multidimensional excitation; parallel excitation; Algorithms; Computer Simulation; Fourier Analysis; Linear Models; Magnetic Resonance Imaging; Radio Waves; Signal Processing, Computer-Assisted;
fLanguage :
English
Journal_Title :
Medical Imaging, IEEE Transactions on
Publisher :
ieee
ISSN :
0278-0062
Type :
jour
DOI :
10.1109/TMI.2009.2020064
Filename :
4915785
Link To Document :
بازگشت