DocumentCode :
859418
Title :
Low Frequency Duty Factor Improvement for the CERN PS Slow Extraction Using RF Phase Displacement Techniques
Author :
Cappi, R. ; Steinbach, Ch.
Author_Institution :
CERN, CH-1211 Geneva 23, Switzerland
Volume :
28
Issue :
3
fYear :
1981
fDate :
6/1/1981 12:00:00 AM
Firstpage :
2806
Lastpage :
2808
Abstract :
The slow extraction spill from synchrotrons is modulated by residual ripple on the power supplies of magnetic elements. Stochastic RF methods. were proposed in the past to improve the poor duty factors of very long extractions (several minutes). Another method, based on RF phase displacement principle is presented here. It is particularly suitable for standard spill lenghts of the order of 1 sec. This operationally simple technique has been studied, tested and implemented on the CERN-PS and has improved the low frequency duty factor from 67 % to 98 % typically for up to 600 ms spills.
Keywords :
Equations; Frequency conversion; Frequency domain analysis; Magnetic modulators; Phase modulation; Power supplies; Radio frequency; Resonance; Synchrotrons; Voltage;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/TNS.1981.4331919
Filename :
4331919
Link To Document :
بازگشت