• DocumentCode
    859771
  • Title

    Measurement and modeling of intense ion beam target heating

  • Author

    Olson, J.C. ; Davis, H.A. ; Waganaar, W.J.

  • Author_Institution
    Los Alamos Nat. Lab., NM, USA
  • Volume
    24
  • Issue
    1
  • fYear
    1996
  • fDate
    2/1/1996 12:00:00 AM
  • Firstpage
    65
  • Lastpage
    66
  • Abstract
    Intense ion beam heating of targets has been assessed as a function of the orientation of the target with respect to the beam. A Monte Carlo code has been used to determine the relative energy deposited per unit mass in targets normal to and at 45° to the beam axis. Assumptions about the distribution of ion trajectories used in the calculations are checked by comparison with thermal images of targets exposed to the beam. Peak energy deposition per unit mass is found to be comparable for both target orientations
  • Keywords
    Monte Carlo methods; focused ion beam technology; heating; infrared imaging; ion beam applications; particle beam diagnostics; vapour deposition; Monte Carlo code; energy deposition; intense ion beam target heating; ion trajectory distribution; modeling; target orientation; thermal images; Area measurement; Focusing; Heating; Infrared imaging; Ion beams; Monte Carlo methods; Pulse measurements; Substrates; Thermal conductivity; Trajectory;
  • fLanguage
    English
  • Journal_Title
    Plasma Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0093-3813
  • Type

    jour

  • DOI
    10.1109/27.491693
  • Filename
    491693