Abstract
The power supply system that will energize the superconducting magnets in the ISABELLE 400 Ã 400 GeV accelerator must supply various voltages and currents. The voltages for the correction winding range from ten to one hundred twenty-five volts unipolar and bipolar with current rating of 50 to 300 amperes. The main field winding requires voltages from 90V (at flattop) to 600V during maximum ramp rate or acceleration cycle. The power supplies are programmable over their full range of output current with a reproducibility error varying from +10 ppm to +400 ppm of full scale. Included within the reproducibility error are the long and short term stability requirements of the power supplies. The purpose of this paper is to define some of the design goals and outline the approach taken in reaching these goals.
Keywords
Acceleration; Accelerator magnets; Magnetic analysis; Performance analysis; Power supplies; Reproducibility of results; Stability; Superconducting magnets; System performance; Voltage;