Title :
The Injection Kicker System of the CERN Antiproton Accumulator
Author :
Fiander, D. ; Metzmacher, K. ; Milner, S. ; Pearce, P. ; Poncet, A. ; Schnuriger, J.-C. ; Wikberg, T.
Author_Institution :
CERN, Geneva, Switzerland
fDate :
6/1/1981 12:00:00 AM
Abstract :
The antiprotons produced at the target are deflected onto the injection orbit by a kicker magnet. The beam emittance demands a very large kicker aperture and bunch interval imposes a short fall-time of the field pulse. A movable fast shutter shields the stack space from pulsed stray field and permits a free passage from injection to stack orbit within each injection cycle. The ferrite delay-line kicker, the servodriven shutter and the ultra high vacuum (UHV) tanks are described. Pulsed magnetic field measurements and operating experience with this kicker system are also reported.
Keywords :
Apertures; Assembly; Blades; Conducting materials; Delay; Ferrites; Impedance; Inductance; Magnetic separation; Voltage;
Journal_Title :
Nuclear Science, IEEE Transactions on
DOI :
10.1109/TNS.1981.4331969