DocumentCode :
860340
Title :
Determination of Transverse Phase-Space and Momentum Error from Size Measurements along the 50-MeV H- RCS Injection Line
Author :
Cho, Yanglai ; Crosbie, Edwin A. ; Takeda, Harunori
Author_Institution :
Argonne National Laboratory Argonne, Illinois 60439
Volume :
28
Issue :
3
fYear :
1981
fDate :
6/1/1981 12:00:00 AM
Firstpage :
3046
Lastpage :
3048
Abstract :
The 50-MeV H- injection line for the RCS at Argonne National Laboratory has 16 quadrupole and eight bending magnets. Horizontal and vertical profiles can be obtained at 12 wire scanner positions. Size information from these profiles can be used to determine the three ellipses parameters in each plane required to describe the transverse phase space. Those locations that have dispersion permit the momentum error to be used as a fourth fitting parameter. The assumed accuracy of the size measurements provides an error matrix that predicts the rms errors of the fitted parameters.
Keywords :
Dispersion; Electron beams; Equations; Government; Laboratories; Magnets; Scattering; Size measurement; Spline; Wire;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/TNS.1981.4332003
Filename :
4332003
Link To Document :
بازگشت