Title :
The Operation of Multipole Magnets in the SRS
Author_Institution :
Science Research Council, Daresbury Laboratory, Daresbury, Warrington WA4 4AD, U.K.
fDate :
6/1/1981 12:00:00 AM
Abstract :
Multipole magnets capable of generating both a strong sextupole field for chromaticity correction and other correction fields ranging from dipole to decapole in any orientation have been installed in the Synchrotron Radiation Source (SRS) at Daresbury. The design of the magnets, the results of magnetic measurements and the method of computer control are described. Details of their operation during commissioning of the storage ring are presented.
Keywords :
Coils; Councils; Electrons; Laboratories; Magnetic variables measurement; Magnets; Shape control; Steel; Storage rings; Synchrotron radiation;
Journal_Title :
Nuclear Science, IEEE Transactions on
DOI :