• DocumentCode
    861421
  • Title

    Identification of volume elements in a 3-D X-ray imaging system

  • Author

    Evans ; Robinson ; Godber

  • Author_Institution
    Dept. of Electr. & Electron. Eng., Nottingham Trent Univ., UK
  • Volume
    32
  • Issue
    7
  • fYear
    1996
  • fDate
    3/28/1996 12:00:00 AM
  • Firstpage
    644
  • Lastpage
    645
  • Abstract
    The way in which 3-D information is produced in a line-scan based stereoscopic X-ray imaging system is examined. The concept of a depth plane is derived from the volume element (voxel) structure created in the image production process. Thus a stereoscopic X-ray image can be considered to be comprised of a series of parallel depth planes. The results presented here quantify the incremental distribution in range between these planes together with the implied lateral resolution present in each plane. This research is part of an ongoing programme to quantify 3-D data in security X-ray screening applications
  • Keywords
    X-ray imaging; inspection; security; stereo image processing; 3D X-ray imaging system; depth plane; lateral resolution; line-scan based stereoscopic imaging; volume elements identification;
  • fLanguage
    English
  • Journal_Title
    Electronics Letters
  • Publisher
    iet
  • ISSN
    0013-5194
  • Type

    jour

  • DOI
    10.1049/el:19960440
  • Filename
    491873