Title : 
Comparing electrode configurations for electrical impedance tomography
         
        
            Author : 
Booth, M.J. ; Basarab-Horwath, I.
         
        
            Author_Institution : 
Sch. of Eng. Inf. Technol., Sheffield Hallam Univ., UK
         
        
        
        
        
            fDate : 
3/28/1996 12:00:00 AM
         
        
        
        
            Abstract : 
Several applications of electrical impedance tomography (EIT) exist where the electrodes can be placed within the interrogated region. The image quality and calculated visibility for various sized conducting anomalies were used as measures of performance for three different electrode configurations. A novel distributed electrode configuration showed superior measures of performance
         
        
            Keywords : 
electric impedance imaging; electrodes; image reconstruction; image resolution; tomography; conducting anomalies; distributed electrode; electrical impedance tomography; electrode configurations; image quality; interrogated region; visibility;
         
        
        
            Journal_Title : 
Electronics Letters
         
        
        
        
        
            DOI : 
10.1049/el:19960414