    The ECAT HRRT: NEMA NEC evaluation of the HRRT system, the new high-resolution research tomograph

  • Author

    Eriksson, L. ; Wienhard, K. ; Eriksson, M. ; Casey, M.E. ; Knoess, C. ; Bruckbauer, T. ; Hamill, J. ; Schmand, M. ; Gremillion, T. ; Lenox, M. ; Conti, M. ; Bendriem, B. ; Heiss, W.D. ; Nutt, R.

  • Author_Institution
    CTI PET Syst. Inc., Knoxville, TN, USA
  • Volume
    49
  • Issue
    5
  • fYear
    2002
  • fDate
    10/1/2002 12:00:00 AM
  • Firstpage
    2085
  • Lastpage
    2088
  • Abstract
    The ECAT HRRT (high-resolution research tomograph) is a three-dimensional(3-D)-only dedicated brain positron emission tomograph (PET) with LSO and GSO scintillators. The system is based on eight panels of detectors. The HRRT´s imaging performance has previously been tested with phantoms and FDG scans performed in animal and human brains that showed significantly improved spatial resolution, below 2.5 mm for animal studies and below 3 mm for brain studies. The NEC count rate performance has been evaluated based on the NU 2-2001 protocol. The results show a peak NEC approximately 30% higher than the performance of the ECAT HR+, this in spite of a more shallow detector for the HRRT, only 15 mm relative to the 30 mm for the HR+. However, peak NEC as derived from the 70-cm line source phantom is not optimized for the performance of dedicated brain scanner. NEC data derived with a 20-cm diameter, 20-cm long phantoms show a peak NEC more than 60% higher than for the HR+. The reasons for the high performance are due to several factors, the large axial coverage, the short timing window of 6 ns, and the low detector dead time, all factors that imply the use of fast LSO and GSO scintillators.
  • Keywords
    Monte Carlo methods; brain; positron emission tomography; solid scintillation detectors; 20 cm; ECAT high-resolution research tomograph; GSO scintillators; Gd2SiO5; LSO scintillators; Lu2SiO5; Monte Carlo simulations; NEC count rate performance; NEC data; animal brains; dedicated brain scanner; detector dead time; detectors; high-resolution research tomograph system; human brains; imaging performance; line source phantom; panels; spatial resolution; three-dimensional-only dedicated brain positron emission tomograph; Animals; Detectors; High-resolution imaging; Humans; Imaging phantoms; National electric code; Performance evaluation; Positron emission tomography; Radioactive decay; Testing;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.2002.803784
  • Filename
    1046794