DocumentCode :
862461
Title :
Low noise HTS gradiometers and magnetometers constructed from YBa/sub 2/Cu/sub 3/O/sub 7-x//PrBa/sub 2/Cu/sub 3/O/sub 7-y/ thin films
Author :
Keene, M.N. ; Satchell, J.S. ; Goodyear, S.W. ; Humphreys, R.G. ; Edwards, J.A. ; Chew, N.G. ; Lander, K.
Author_Institution :
Defence Res. Agency, Malvern, UK
Volume :
5
Issue :
2
fYear :
1995
fDate :
6/1/1995 12:00:00 AM
Firstpage :
2923
Lastpage :
2926
Abstract :
D.C. SQUID based gradiometers and magnetometers have been fabricated using thin films of YBa/sub 2/Cu/sub 3/O/sub 7/ and PrBa/sub 2/Cu/sub 3/O/sub 7/ on MgO substrates. Flip-chip magnetometers with 1 cm and 6.25 cm/sup 2/ substrates have been constructed. Our device on the larger substrate with a 430 mm/sup 2/ pickup loop had a sensitivity of (42/spl plusmn/3) fT//spl radic/Hz above 3 Hz and (75/spl plusmn/7) fT//spl radic/Hz at 1 Hz. Numerical simulations of d.c. SQUIDs at 77 K have been conducted over an inductance range from 2 to 1000 pH and a critical current range from 3.2 to 322 /spl mu/A. The results emphasise the need to reduce SQUID inductances in order to obtain lower flux noise. Three layer gradiometric SQUIDs with c-axis microbridge junctions and low inductance have been fabricated. First order gradiometric flux transformers were also made with twin 20 turn spiral SQUID input coils and a pair of larger area balanced sensing coils. These were mounted with the gradiometric SQUIDs in a flip chip configuration to complete the highly symmetrical gradiometers. Measurements at 79 K on one gradiometer gave a gradient sensitivity of (49/spl plusmn/3) pT/m//spl radic/Hz at 300 Hz and (103/spl plusmn/7) pT/m//spl radic/Hz at 1 Hz.<>
Keywords :
SQUID magnetometers; barium compounds; critical current density (superconductivity); electron device manufacture; flip-chip devices; high-temperature superconductors; praseodymium compounds; superconducting coils; superconducting device noise; superconducting microbridges; superconducting thin films; yttrium compounds; 1 to 3 Hz; 3.2 to 322 muA; 300 Hz; 77 to 79 K; DC SQUIDs; YBa/sub 2/Cu/sub 3/O/sub 7/-PrBa/sub 2/Cu/sub 3/O/sub 7/; balanced sensing coils; c-axis microbridge junctions; critical current range; flip-chip magnetometers; flux noise; gradient sensitivity; gradiometric flux transformers; inductance range; low noise HTS gradiometers; low noise HTS magnetometers; pickup loop; sensitivity; Coils; Critical current; High temperature superconductors; Inductance; Noise reduction; Numerical simulation; SQUID magnetometers; Spirals; Transformers; Transistors;
fLanguage :
English
Journal_Title :
Applied Superconductivity, IEEE Transactions on
Publisher :
ieee
ISSN :
1051-8223
Type :
jour
DOI :
10.1109/77.403204
Filename :
403204
Link To Document :
بازگشت