DocumentCode
862765
Title
A Photodiode - Readout (SPED) Sampling Calorimeter
Author
Kononenko, W. ; Selove, W. ; Theodosiou, G. ; Van Berg, R.
Author_Institution
University of Pennsylvania, Department of Physics Philadelphia, PA 19104
Volume
30
Issue
1
fYear
1983
Firstpage
125
Lastpage
126
Abstract
We have built and tested a new type of sampling calorimeter using scintillator as the active material, and thin vacuum photodiodes for signal readout, the new feature. We measured an energy resolution of about 22%/¿E for electrons of 10-37.5 GeV. For muons the signal to noise ratio is somewhat greater than 2. The main merits of such a design are the excellent gain stability (gain = 1), absence of the need for high voltages or for highly stabilized voltages or for elaborate calibration systems, and the ability to operate in high magnetic fields.
Keywords
Electrons; Energy measurement; Energy resolution; Materials testing; Mesons; Photodiodes; Sampling methods; Signal to noise ratio; Stability; Voltage;
fLanguage
English
Journal_Title
Nuclear Science, IEEE Transactions on
Publisher
ieee
ISSN
0018-9499
Type
jour
DOI
10.1109/TNS.1983.4332233
Filename
4332233