DocumentCode :
863135
Title :
Use of excess height and cluster extent in subtraction SPECT
Author :
Baete, Kristof ; Nuyts, Johan ; Van Paesschen, Wim ; Maes, Alex ; Ghoorun, Shivani ; Suetens, Paul ; Dupont, Patrick
Author_Institution :
Dept. of Nucl. Medicine, Univ. Hosp. Gasthuisberg, Leuven, Belgium
Volume :
49
Issue :
5
fYear :
2002
fDate :
10/1/2002 12:00:00 AM
Firstpage :
2332
Lastpage :
2337
Abstract :
Subtraction of ictal and interictal single photon emission computed tomography (SPECT) perfusion images of the brain has the potential of locating the epileptogenic region. This region generally shows large differences between both images. However, differences can also be induced by noise in the projection data. We hypothesized that the extent, besides the intensity, of observed clusters of voxels in thresholded subtraction images, is an important parameter in the classification of clusters into real perfusion differences and noise-induced differences. To test this hypothesis, we performed a number of simulation experiments. Using a Monte Carlo approach, we constructed cumulative distribution functions (CDFs) of the excess height (i.e., the largest difference in a cluster) and the cluster extent under the condition of no perfusion change (i.e., only noise-induced clusters). The reproducibility of the CDF curves was shown using measured patient data. Furthermore, a three-dimensional (3-D) brain software phantom experiment was used to examine the detection and classification of an induced region of hyperperfusion. In a first experiment, we compared two detection criteria: detection of the induced hyperperfusion based on the observed cluster with the largest excess height and based on the observed cluster with the largest extent. Detection based on the largest extent showed a better sensitivity. In a second experiment, we assigned to every observed cluster a probability, derived from the CDF curves, for excess height and extent. For different probability thresholds, sensitivity and specificity of the detection of the induced hyperperfusion based on its probability for excess height and cluster extent were measured. These measurements were combined in receiver operating characteristic (ROC) curves. These ROC curves showed a better performance when using classification based on cluster extent. We conclude that the cluster extent is an important parameter in the characterization of clusters in thresholded subtraction of perfusion SPELT images of the brain.
Keywords :
Monte Carlo methods; brain; haemorheology; medical computing; medical image processing; neurophysiology; probability; single photon emission computed tomography; Monte Carlo approach; ROC curves; brain; cluster extent; cumulative distribution functions; epilepsy; epileptogenic region; excess height; hyperperfusion; image processing; noise-induced differences; perfusion change; perfusion images; probability; projection data; single photon emission computed tomography; software phantom; subtraction SPECT; thresholded subtraction images; voxels; Distribution functions; Epilepsy; Hospitals; Image analysis; Monte Carlo methods; Nuclear medicine; Performance evaluation; Reproducibility of results; Single photon emission computed tomography; Testing;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/TNS.2002.803682
Filename :
1046913
Link To Document :
بازگشت