Title :
Motion Artifact Reduction in Breast Dynamic Infrared Imaging
Author :
Agostini, Valentina ; Knaflitz, Marco ; Molinari, Filippo
Author_Institution :
Dept. of Electron., Politec. di Torino, Torino
fDate :
3/1/2009 12:00:00 AM
Abstract :
Dynamic infrared imaging is a promising technique in breast oncology. In this paper, a quantum well infrared photodetector infrared camera is used to acquire a sequence of consecutive thermal images of the patientpsilas breast for 10 s. Information on the local blood perfusion is obtained from the spectral analysis of the time series at each image pixel. Due to respiratory and motion artifacts, the direct comparison of the temperature values that a pixel assumes along the sequence becomes difficult. In fact, the small temperature changes due to blood perfusion, of the order of 10-50 mK, which constitute the signal of interest in the time domain, are superimposed onto large temperature fluctuations due to the subjectpsilas motion, which represent noise. To improve the time series S/N, and as a consequence, enhance the specificity and sensitivity of the dynamic infrared examination, it is important to realign the thermal images of the acquisition sequence, thus reducing motion artifacts. In a previous study, we demonstrated that a registration algorithm based on fiducial points is suitable to both clinical applications and research, when associated with a proper set of skin markers. In this paper, we quantitatively evaluate the performance of different marker sets by means of a model that allows for estimating the S/N increment due to registration, and we conclude that a 12-marker set is a good compromise between motion artifact reduction and the time required to prepare the patient.
Keywords :
biological organs; biomedical optical imaging; cancer; haemorheology; image motion analysis; image registration; image sensors; image sequences; infrared detectors; infrared imaging; mammography; medical image processing; photodetectors; skin; spectral analysis; time series; tumours; blood perfusion; breast oncology; dynamic infrared imaging; fiducial points; image sequence; motion artifact reduction; quantum well infrared photodetector infrared camera; registration algorithm; signal-to-noise ratio; skin marker; temperature 10 mK to 50 mK; thermal image acquisition; time 10 s; time series spectral analysis; Blood; Breast; Cameras; Fluctuations; Infrared imaging; Oncology; Photodetectors; Pixel; Spectral analysis; Temperature sensors; $S/N$ estimation; Breast cancer detection; dynamic infrared imaging; image registration; skin markers; thermal image sequence; Adult; Aged; Algorithms; Breast; Breast Neoplasms; Female; Humans; Image Interpretation, Computer-Assisted; Middle Aged; Sensitivity and Specificity; Thermography;
Journal_Title :
Biomedical Engineering, IEEE Transactions on
DOI :
10.1109/TBME.2008.2005584