    Continuous measurement of moisture in nonconducting materials

  • Author

    Vermeulen, Clinton ; Hancke, Gerhard P.

  • Author_Institution
    Dept. of Electr. & Electron. Eng., Pretoria Univ., South Africa
  • Volume
    41
  • Issue
    6
  • fYear
    1992
  • fDate
    12/1/1992 12:00:00 AM
  • Firstpage
    1023
  • Lastpage
    1026
  • Abstract
    A microwave-based system for the continuous measurement of moisture in nonconducting materials is described. The system was implemented on conveyor belts carrying coarse coal. To obtain a reliable measurement for this application, several other factors which influence the microwave measurement technique had to be investigated. These factors are, among others, the mass per unit area and the temperature. The measurement of these factors makes possible the general characterization of the coal, which is important for optimizing the utilization of the coal for various applications
  • Keywords
    coal; microwave measurement; moisture measurement; coarse coal; continuous measurement; conveyor belts; microwave measurement; moisture measurement; nonconducting materials; Dielectric constant; Dielectric loss measurement; Dielectric losses; Dielectric materials; Dielectric measurements; Microwave devices; Microwave measurements; Microwave theory and techniques; Moisture measurement; Permittivity measurement;