Abstract :
Over the last few decades, dynamic focusing based on digital receive beamforming (DRBF) has led to significant improvements in image quality. However, it is computationally very demanding due to its requirement for multiple lowpass filters (e.g., a complex filter for each receive channel in quadrature demodulation-based phase rotation beamform- ers (QD-PRBF)). We recently developed a novel phase rotation beamformer with reduced complexity, which can lower: 1) the number of lowpass filters using 2-stage demodulation (TSD) and 2) the number of beamforming points using adap tive field-of-view (AFOV) imaging. In TSD, dynamic focusing is performed on the mixed signals, while sampling frequency of the beamformed signal (i.e., beamforming frequency) is adjusted based on the displayed field-of-view (FOV) size in AFOV imaging. In this paper, the image quality of the developed beamformer (i.e., TSD-AFOV-PRBF) has been quantitatively evaluated using phantom and in vivo data. From the phantom study, it was found that TSD-AFOV-PRBF with only 1024 beamforming points provides comparable image quality to QD-PRBF. We obtained a median contrast resolution (CR) degradation of 7.6% for the FOV size of 160 mm. Image quality steadily improves with FOV size reduction (e.g., 2.3% CR degradation at 85 mm). Similar results were also obtained from an in vivo study. Thus, TSD-AFOV-PRBF could provide comparable image quality to conventional beamformers at considerably reduced computational cost.
Keywords :
acoustic signal processing; phantoms; ultrasonic imaging; 2-stage demodulation; DRBF; TSD-AFOV-PRBF; adaptive field-of-view imaging; digital receive beamforming; dynamic focusing; image quality evaluation; multiple lowpass filters; phantom; phase rotation beamformer; ultrasound systems; Array signal processing; Chromium; Degradation; Demodulation; Filters; Frequency; Image quality; Image sampling; Imaging phantoms; In vivo; Abdomen; Algorithms; Equipment Design; Equipment Failure Analysis; Humans; Image Enhancement; Image Interpretation, Computer-Assisted; Phantoms, Imaging; Reproducibility of Results; Sensitivity and Specificity; Ultrasonography;
fLanguage :
English
Journal_Title :
Ultrasonics, Ferroelectrics, and Frequency Control, IEEE Transactions on
Publisher :
ieee
ISSN :
0885-3010
Type :
jour
DOI :
10.1109/TUFFC.886
Filename :
4626923
Link To Document :
بازگشت