Abstract :
A hosptial based cyclotron is under installation at The University of Texas M.D. Anderson Hospital in Houston. This machine will be used for the production of radioactive isotopes and for the generation of neutrons for the radiotherapy treatment of cancer. It is a Cyclotron Corporation CP-42 negative proton accelerator. For neutron production the protons are transported through an isocentrically mounted beam transport system that can be rotated around the patient. The shielding requirements of this facility will be described as will the initial measurements on the characteristics of the neutron beam.
Keywords :
Biomedical applications of radiation; Cancer; Cyclotrons; Hospitals; Isotopes; Neutrons; Particle beams; Production; Proton accelerators; Testing;