DocumentCode :
867095
Title :
Digitial Computers in CANDU Safety Systems: Part II Implementation and Experience
Author :
Gilbert, R.S.
Author_Institution :
Atomic Energy of Canada Limited Engineering Company Sheridan Park Research Community Mississauga, Ontario L5K 1B2
Volume :
30
Issue :
3
fYear :
1983
fDate :
6/1/1983 12:00:00 AM
Firstpage :
1912
Lastpage :
1916
Abstract :
Microcomputer based systems have recently been applied to CANDU safety systems. This paper describes three specific systems, a monitoring system, the programmable digital comparator (PDC) system, and a fully computerized shutdown system prototype. The system configurations, the hardware and the software used to implement these designs are discussed. Each of these systems uses commercial off-the-shelf hardware which has been modified and qualified when necessary to meet specific power plant requirements. The preliminary experience which has been gained with the systems already in operation also summarized.
Keywords :
Application software; Computer applications; Computer displays; Computerized monitoring; Hardware; Instruments; Logic; Power generation; Remote monitoring; Safety;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/TNS.1983.4332671
Filename :
4332671
Link To Document :
بازگشت