• DocumentCode
    868001
  • Title

    Beam Dump/Diagnostics Assembly for a 10-kA, 50-MeV, 50-ns Electron Beam

  • Author

    White, J.M. ; Fessenden, T.J. ; Fontaine, R.A. ; Harvey, A.R. ; Paul, A.C.

  • Author_Institution
    Lawrence Livermore National Laboratory P. O. Box 808, L-544 Livermore, CA 94550
  • Volume
    30
  • Issue
    4
  • fYear
    1983
  • Firstpage
    2207
  • Lastpage
    2209
  • Abstract
    We have developed a dump for the ATA beam that consists of a series of carbon plates whose collective thickness totals approximately 1.5 ranges at 50 MeV. The energy dissipated in the plates is radiated to a water cooled wall. The dump is designed to dissipate up to 175 kW of average power. A small hole along the axis of the plates forms a beamlet that passes through an energy analyzer. The analyzer consists of a 60° bending magnet and two high sensitivity beam current/positon monitors. The ratio of the beamlet current to full current is used to estimate the beam emittance.
  • Keywords
    Assembly; Collimators; Computer bugs; Current measurement; Electron beams; Energy measurement; Extraterrestrial measurements; Laboratories; Magnetic analysis; Particle beams;