• DocumentCode
    868256
  • Title

    Status of the SLAC Snoop Diagnostic Module for FASTBUS

  • Author

    Walz, Helmut V. ; Gustavson, David B.

  • Author_Institution
    Stanford Linear Accelerator Center Stanford University, Stanford, California 94305
  • Volume
    30
  • Issue
    4
  • fYear
    1983
  • Firstpage
    2276
  • Lastpage
    2278
  • Abstract
    A SNOOP Diagnostic Module for FASTBUS is under development at SLAC. The SNOOP Module resides on a FASTBUS crate segment and provides diagnostic monitoring and testing capability. It consists of a high-speed ECL front-end to monitor and single-step segment operations, a simple master interface, and a control processor with two serial communication ports. Module features and specifications are summarized, and prototype hardware is shown.
  • Keywords
    Clocks; Communication system control; Delay; Fastbus; History; Logic; Master-slave; Monitoring; Read-write memory; Testing;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.1983.4332787
  • Filename
    4332787