DocumentCode :
869691
Title :
Voltage-Clamped Class-E Inverter With Harmonic Tuning Network for Magnetron Drive
Author :
Woo, Young-Jin ; Kim, Sang-Kyung ; Cho, Gyu-Hyeong
Author_Institution :
Dept. of Electr. Eng. & Comput. Sci., Korea Adv. Inst. of Sci. & Technol., Daejeon
Volume :
53
Issue :
12
fYear :
2006
Firstpage :
1456
Lastpage :
1460
Abstract :
A passive lossless snubber utilizing harmonic resonance is proposed for the voltage-driven class-E inverter. This snubber reduces the peak resonant voltage stress across the switch in class-E operation by adding the third-order harmonic current into the fundamental resonant part and can be extended to a higher-order network for further reduction. Though the principle is actually equivalent to the class-F operation in RF power amplifiers, it is first tried for the class-E inverter without a current source inductor. A series of analyses is performed to find component values that provide the optimum harmonic condition, and the experimental results from the inverter power supply for driving a magnetron are presented
Keywords :
constant current sources; driver circuits; invertors; magnetrons; power amplifiers; RF power amplifiers; class-E inverter; current source inductor; harmonic current; harmonic resonance; harmonic tuning network; magnetron drive; voltage stress; Inverters; Magnetic resonance; Operational amplifiers; Power amplifiers; Radio frequency; Radiofrequency amplifiers; Snubbers; Stress; Switches; Voltage; Class E; class F; harmonic resonance; induction heating (IH); microwave oven (MWO); snubbers;
fLanguage :
English
Journal_Title :
Circuits and Systems II: Express Briefs, IEEE Transactions on
Publisher :
ieee
ISSN :
1549-7747
Type :
jour
DOI :
10.1109/TCSII.2006.884121
Filename :
4033175
Link To Document :
بازگشت