Title :
Determination of octantal error on a 4-element adcock direction finder
Author_Institution :
Government Communications Headquarters, Cheltenham, UK
fDate :
10/1/1966 12:00:00 AM
Abstract :
It is shown that bearings taken on a signal with a 4-element Adcock direction finder can be corrected for octantal error by means of an additional measurement made on the signal. A suitable measurement would be a comparison of the sum signals (N + S) and (E + W).
Keywords :
antennas; measurement;
Journal_Title :
Electronics Letters
DOI :