Title :
A New Front-End High-Resolution Sampling Board for the New-Generation Electronics of EXOGAM2 and NEDA Detectors
Author :
Egea Canet, F.J. ; Gonzalez, V. ; Tripon, M. ; Jastrzab, M. ; Triossi, A. ; Gadea, A. ; de France, G. ; Valiente-Dobon, J.J. ; Barrientos, D. ; Sanchis, E. ; Boujrad, A. ; Houarner, C. ; Blaizot, M. ; Bourgault, P. ; de Angelis, G. ; Erduran, M.N. ; Ertur
Author_Institution :
Escola Tec. Super. d´Eng., Dept. d´Eng. Electron., Univ. de Valéncia, Valencia, Spain
Abstract :
This paper presents the final design and results of the FADC Mezzanine for the EXOGAM (EXOtic GAMma array spectrometer) and NEDA (Neutron Detector Array) detectors. The measurements performed include those of studying the effective number of bits, the energy resolution using HP-Ge detectors, as well as timing histograms and n/γ discrimination performance. Finally, the conclusion shows how a common digitizing device has been integrated in the experimental environment of two very different detectors which combine both low-noise acquisition and fast sampling rates. Not only the integration fulfilled the expected specifications on both systems, but it also showed how a study of synergy between detectors could lead to the reduction of resources and time by applying a common strategy.
Keywords :
gamma-ray spectrometers; germanium radiation detectors; neutron detection; EXOGAM2 detectors; FADC Mezzanine; HP-Ge detectors; NEDA detectors; front-end high-resolution sampling board; gamma exotic array spectrometer; neutron detector array; new-generation electronics; Bandwidth; Detectors; Energy measurement; Energy resolution; Noise; Signal resolution; Timing; Acquisition in HP-Ge detectors; high-speed ADCs; low-noise electronics design;
Journal_Title :
Nuclear Science, IEEE Transactions on
DOI :
10.1109/TNS.2015.2433021