DocumentCode :
870500
Title :
Optical measurement of non-uniform electric field vector distribution in a dielectric liquid using triplet measurement system [and reply]
Author :
Zahn, M. ; Ustundag, A. ; Ihori, Haruo ; Fujii, Masahiro ; Arii, K.
Author_Institution :
Dept. of Electr. Eng. & Comput. Sci., MIT, Cambridge, MA
Volume :
9
Issue :
6
fYear :
2002
fDate :
12/1/2002 12:00:00 AM
Firstpage :
972
Lastpage :
974
Abstract :
The authors argue that the original paper by Ihori et al. ("Optical Measurement of Non-uniform Electric Field Vector Distribution in a Dielectric Liquid Using Triplet Measurement System", see ibid., vol. 9, p. 56-60, 2002) is misleading. The purpose of this communication is to point out the mis-statements and to identify the nature of the unstated approximations used in that work.
Keywords :
dielectric liquids; electric breakdown; electric field measurement; insulation testing; optical variables measurement; dielectric liquid; nonuniform electric field vector distribution; optical measurement; paper discussion; triplet measurement system; Dielectric liquids; Dielectric measurements; Electric variables measurement; Geometry; Mathematics; Maxwell equations; Noise measurement; Nonuniform electric fields; Time measurement; White noise;
fLanguage :
English
Journal_Title :
Dielectrics and Electrical Insulation, IEEE Transactions on
Publisher :
ieee
ISSN :
1070-9878
Type :
jour
DOI :
10.1109/TDEI.2002.1115492