Title :
Comparison between measured and theoretical nonlinear behaviour of 4-cavity klystrons
Author :
Eaton, J.L. ; Whythe, D.J.
Author_Institution :
BBC, Research Department, Tadworth, UK
fDate :
2/1/1967 12:00:00 AM
Abstract :
Measured distortions of television signals and levels of harmonics and intermodulation products occurring in a 4-cavity klystron are shown to be in reasonable agreement with values calculated using the 2-cavity ballistic theory. It is concluded that the measured nonlinearity of the klystron is largely fundamental to its mode of operation.
Journal_Title :
Electronics Letters
DOI :
10.1049/el:19670043