Title :
Determination of the Ionic Conductivity of Ionized Air with a Resonant Cavity
Author :
Ambrose, L. ; Bushell, M. ; Hirschorn, E. ; Kenyon, C. ; Merkel, G. ; Scharf, W.D.
Author_Institution :
US Army Electronics Research and Development Command Harry Diamond Laboratories 2800 Powder Mill Road Adelphi, MD 20783
Abstract :
A resonant cavity technique has been employed to measure the ratio of the average ionic mobility, ¿i , to the ionic recombination constant, k , for ionized air (water content 1.1 ± 0.1% by volume). The measured value is ¿i/k = 0.8Ã108(m-1V-1). The result is compared with measurements made with other techniques. A possible basis for the variation of published values is the variation of humidity in the air sample measured.
Keywords :
Conductivity measurement; Differential equations; Electron mobility; Laboratories; Milling machines; Powders; Research and development; Resonance; Spontaneous emission; Thermal conductivity;
Journal_Title :
Nuclear Science, IEEE Transactions on
DOI :
10.1109/TNS.1983.4333174